3.19.5 arsmnst - Moving shock relations given T2/T1
SUBROUTINE AR18AD(G,T,RESULT,IERR)
  DOUBLE PRECISION G, T, RESULT(4)
  INTEGER IERR

Compute the moving normal shock wave relations given the temperature ratio T2/T1   .

Performance
Fixed

Arguments




Argument Intent

Description




g in

Specific heat constant γ .

t in

Temperature ratio         2         2
T2/T1> (γ + 1)/(γ+1)   .

result out

Array with result properties as described in  16.

ierr out

(optional) Return status code




Status codes

-1

Specific heat ratio γ≤ 1  .

-2

Computed M out of range.