Compressible Flow Subroutine Library
Programming Reference Manual
Version 1.0 DD-00008-110E

3.14.3 arsefp - Expansion fan properties given p2/p1   and either M1   or M2
SUBROUTINE AR14AB(G,P,M,IS_M2,RESULT,IERR)
  DOUBLE PRECISION G, P, M, RESULT(5)
  LOGICAL IS_M2
  INTEGER IERR

Compute the expansion fan properties given p2/p1   and either M1   or M2   .

Performance
Fixed

Arguments

G - REAL

ENTRY: Specific heat constant γ .

P - REAL

ENTRY: Pressure ratio p /p
 2  1   .

M - REAL

ENTRY: Either M  ≥1
 1  or M  >0
 2  depending on whether is_m2 is false or true, respectivly.

IS_M2 - BOOLEAN

ENTRY: Whether the given m refers to M
  1   or M
 2   .

RESULT - ARRAY OF REAL

EXIT: Array with result properties as described in  12.

IERR - INTEGER

EXIT: (optional) Return status code.

Status codes

-1

Specific heat ratio γ≤ 1  .

-2

Given M1   or M2   out of range.

-3