3.10.4 arsnsp - Normal shock relations given p2/p1
SUBROUTINE AR10AC(G,P,RESULT,IERR)
  DOUBLE PRECISION G, P, RESULT(5)
  INTEGER IERR

Compute the normal shock relations given the pressure ratio p2/p1   .

Performance
Fixed

Arguments

G - REAL

ENTRY: Specific heat constant γ .

P - REAL

ENTRY: Pressure ratio p /p  <1
 2  1  .

RESULT - ARRAY OF REAL

EXIT: Array with result properties as described in  8.

IERR - INTEGER

EXIT: (optional) Return status code.

Status codes

-1

Specific heat ratio γ≤ 1  .

-2

Computed M1n out of range.

-3

Given p2/p1   out of range.