Compressible Flow Subroutine Library
Programming Reference Manual
Version 1.0 DD-00008-110E

3.10.6 arsnst - Normal shock relations given T2/T1
SUBROUTINE AR10AE(G,T,RESULT,IERR)
  DOUBLE PRECISION G, T, RESULT(5)
  INTEGER IERR

Compute the normal shock relations given the temperature ratio T2/T1   .

Performance
Fixed

Arguments

G - REAL

ENTRY: Specific heat constant γ .

T - REAL

ENTRY: Temperature ratio T /T ≥ 1
  2 1  .

RESULT - ARRAY OF REAL

EXIT: Array with result properties as described in  8.

IERR - INTEGER

EXIT: (optional) Return status code.

Status codes

-1

Specific heat ratio γ≤ 1  .

-2

Computed M1n out of range.

-3

Given T2/T1   out of range.