q = muller_q(l,d,p1,p2,pb,tb,tf,z,e,mu,sg=1)
Calculate the volume flow using the Muller equation.
Length of the pipe ().
Diameter of the pipe ().
Upstream pressure ().
Downstream pressure ().
Base pressure ().
Base temperature ().
Average temperature ().
Gas compressebility factor.
Pipeline efficiency factor.
Average viscosity in the pipeline ().
Gas gravity ().